In practical terms, the static CR cannot be increased enough to overcome loss of low speed torque with a late intake closure.
You can get the DCR to match, but the same CCP is acting on a smaller cylinder (using only the stroke length from the IVC point).
A mild 292 (8:1, IVC 37 degrees) CCP = 150 lbs., the cylinder volume is 270" with the remaining stroke. Estimate torque @ 1,000 RPM: 288.
A warm 292 (11:1, IVC 82 degrees) CCP = 150 lbs., the cylinder volume is 188" with the remaining stroke. Est. torque: 199.